We use cookies to ensure that we give you the best experience on our website Learn more

Home

Saved research

Submission

A 10-Year Retrospective Study on Cemented Versus Screw Retained Implant Abutment Connection

Submitted

and 3 other(s)

44 Views
0 Downloads
1 Saves

Presented at

EAO-2018

-

Presentation

thumbnail

Abstract

A large number of studies described implant survive and their short and long-term success with 94.6% early success rates and 89.7% even after more than 10 years of function. The failure of implant supported rehabilitation was either mechanical or biological. Few studies have conducted follow-ups for more than 10 years with regard to specific fixture-abutment connection. The aim of this retrospective study is to evaluate the long-term reliability and the incidence of technical and biological complications on single crowns supported by: cement retained abutment (CRA) and screwed retained abutment (SRA). A total of 300 single implant supported crowns performed from 2004 to 2007 on 300 different patients aged between 40 and 75 years were analyzed. Patients were divided in 150 group A (SRA) and 150 group B (CRA) selecting by inclusion criteria.The research was so performed: periapical radiographs performed with bite block, where crestal bone resorption (RC) was measured. The values were classified in three categories: <2 mm, between 2 and 4 mm, and greater than 4 mm. Bleeding on probing (BOP) and probing depth (PD) were measured. A cut-off of 5mm was taken related to PD: >5 mm was considered a negative outcome. Prosthetic complications were recorded: abutment decementation, screw loosening and prosthetic fracture. The results were analyzed for statistical analysis. The data analysis showed a rate of 4% of implant failure during the 10 years follow up period. Therefore this data were not taken into consideration for complication analysis. Regarding biological aspect, results showed a positive BOP index at 84.2% of the sites under investigation. Specifically, SRA showed a BOP of 86,5% and CRA 81,4%. More over the probing depth (PD) >5mm on peri-implant soft tissues analysis demonstrated a rate of 20,9% for CRA and 13,8% for SRA. The crestal bone loss radiographic measurements demonstrated for the range of RC < 2 mm, a value of 16% for SRA and 62% for CRA; RC >2<4 mm 70% for SRA and 31% for CRA and at the end RC > 4mm revealed a 14% for SRA whilst 7 % for CRA. Regarding mechanical aspect of connection a total of 14,6% of complications occurred: 6,2% for SRA and 8,33% for CRA. Finally, about prosthetic aspects: 7,6% crown fracture for SRA and 2,78 %for CRA. The results from this 10-year retrospective study showed that the two methods have positive long-term follow-ups, although the complications encountered. RC was statistically greater in the SRA group. In this regard, the possibility of having a better coupling between parts in the CRA method encourages the clinical use of these in terms of lower bone resorption values and screw loosening.

Datasets

No datasets are available for this submission.

License

No license information is available for this submission.

Morressier

Company

Legal

Follow us

© Copyright 2020 Morressier GmbH. All rights reserved.

Morressier

© Copyright 2020 Morressier GmbH.
All rights reserved.